Motor Branch-Circuit and Voltage Drop
Calculator (BETA
Version)
electrician2.com (60 HZ Alternating Current induction type
1-phase & 3-phase, wound rotor, and under 600 volt motors
) |
|
| Motor AC Voltage |
Horsepower (Notes 5 - 9) |
Phase (Notes 5 - 9) |
Type of Motor (Note 10) |
Class of Service
(Notes 1 &
2) |
Duty-Cycle Service (Notes 1 & 2) |
|
|
|
|
|
|
|
Enter NamePlate Current Required If Class of
Service is other than Continuous. Optional otherwise. Note
21 |
Conductor Material
|
Ambient Temperature C
|
Number Current Carrying
Conductors in Raceway or Cable or bundle
|
| Service Factor is 1.15 or
greater |
Special Conditions |
| Temp rise is not over 40
Degrees C. |
| Select Conductor
Insulation Temperature Note 22
|
Select Termination Temperature
C.
|
Circuit conductors
are bundled or in raceway 24 inches or less in length |
Conductors are
in Type AC or MC cable that complies with Note
3. |
|
Yes |
|
Yes |
|
|
No |
|
No |
|
|
CLICK BUTTON FOR OUTPUTS
BELOW |
|
|
|
Conductor Size |
Motor branch-circuit short-circuit and ground-fault
protection (percentage of FLA from Tables 430.248 and
430.250) |
|
1-phase and 3-phase motor
outputs |
| Equipment Grounding
Conductor Size (Note 23) |
non time delay fuse (300% ) |
dual element time delay fuse
(175%) |
instantaneous trip circuit
breaker (800% or 1100% -design B) |
inverse time trip circuit breaker
(250%) |
|
|
|
|
|
|
|
Maximum Values see Note
11 |
Motor
Disconnect Size (Note 17) amperes minimum
or
hp rated
switch (min) |
a) 400% for fuses not
greater than 600 amperes b) 300% for fuses of 601 to 6000 ampere
classification Notes 12 & 16 |
225% Note 13 |
1300% 1700% for Design B Note 14 |
a) 400% for FLA of 100 amperes or less b) 300% FLA is
greater than 100 amperes Note 15 |
|
Controller NEMA size Notes 18, 19, &
20 |
|
Overload Protection (Note 21)
normal max size 430.32
max relay size 430.34 |
|
|
|
|
|
Wound Rotor Motor outputs |
non time delay fuse (
150%) |
dual element time delay fuse
(150%) |
instantaneous trip circuit
breaker (800%) |
inverse time trip circuit breaker
(150%) |
|
|
|
|
|
|
Data |
Conductor Derated ampacity
|
Terminal Ampacity
|
AC or MC Cable Derating Factor (if applicable)
|
Ambient Correction Factor
|
Total Load
|
Terminal Load (total
load)
|
Full Load
amperes
(FLA)
|
Conductor Derating Factor for more
than three current carrying conductors
|
Conductor
ampacity
|
Conductor circular mil
area
|
Total conductor ampacity
Derating Factor
|
| |
Motor Full Load
Amperes Current Multiplier (for continuous duty
Class of Service)
|
Nameplate current
multiplier (for other than continuous duty Class of Service ) see Note
4
|